Products

FIRE ALARM SYSTEM - FIRE GUARD

ADDRESSABLE  FIRE ALARM SYSTEM

  • As per UL 864, 9th Edition & NFPA 72
  • 32bit Processor Arm Cortex M3
  • Expandable up to 4-8 loops
  • Touch Keypad.
  • 160 Characters LCD Display (40×4).
  • 254 Devices per loop.
  • USB 2.0 Built -in PC Interface.
  • Day & Night Mode Facility.
  • Drift Compensation / Maintenance Alert.
  • Extensive built-in Transient Protection.
  • Redundancy.
  • 192 Grouping with Labeling

  • Zone Wise Pre-Alarm Action.
  • Multi protocol.
  • Trouble Reminder.
  • Inbuilt RS485 Network Card.
  • One Inbuilt Conventional Zone.
  • One Inbuilt Remote Input.
  • Auto Learn Facility.
  • 2000 Events(1000 Fire + 1000 Others ).
  • On Board 3 Programmable Relays.
  • Fire, Fault, Supervisory and Pre Alarm.  

HEAT DETECTOR-MULTI DETECTOR

  • DIP-switch addressed smoke detector for 2-wire systems
  • Stable photoelectric smoke sensing chamber.
  • No adjustment or replacement required.
  • An electronic thermistor sensor provides sensitive rate-of rise alarm operation, or fixed-temperature operation when the response threshold value is exceeded.
  • Dual LEDs for 360° visibility
  • Easy installation with simple address setting DIP switches
  • Up to 254 detectors can be connected to each alarm zone loop.

 ADDRESSABLE MANUAL PULL STATION

  • High Quality Non Toxic Die casting.
  • Plated surfaces to inhibit corrosion
  • With or without Break Glass rod
  • Easily replaceable break glass road without special tools.
  • Single Gang Mounting.
  • 10 Amp@ 120VAC SPST.
  • Available with FLAP and without FLAP.
  • Available in Red, Green and Yellow Color.

BEAM DETECTOR WITH REFLECTOR

  • 5-100 Meter Range.
  • Auto Alignment.
  • Quick commissioning.
  • Available in 3 variants.
  • 5-40m,40-80m & 80 -100m.

MONITOR MODULE

  • Monitor modules are used to monitor any third party system change in state by using potential free contacts like water flow switches, Pressure switches, pull stations, etc.
  • Supervisory input circuit is available to monitor the circuitry of third party system.

CONTROL MODULE

  • To Switch the Notification application devices bells, sounder, strobe, sounder cum strobe etc.
  • For the programmed input devices.
  • Monitoring the 24vdc supply which is used to activate the Notification Appliances.
  • Supervising the Notification appliance devices and its cabling.

INPUT OUTPUT MODULE

  • Combination of One Input and One output Module.
  • Single Module Consumes dual address.
  • 1st address assigned by Default for input and 2nd device for Output Modules.
  • Output Module shall be programmable for any logic.
  • Blinking RED LED for Status indication.
  • Constant RED LED for Alarm indication.

ZONE INTERFACE MODULE

 

  • Interfacing Conventional Devices to Addressable FAP.
  • Monitors the Status of Normal, Open, Short and Fire on IDCs.
  • Supervisory IDCs. Supervisory Auxiliary Power Supplies.
  • Blinking RED LED for Status indication.
  • Constant RED LED for Alarm indication
  • Resettable 24VDC output
  • Configurable wiring Class

ISOLATOR BASE

  • Isolator Base is a Base to protect the panel from wire to wire short circuit .
  • Isolates the high voltage from the field cabling to the panel. Powered by SLC directly.
  • Blinking LED for normal Conditions and Steady LED for short circuit identification.
  • Auto resetting to normal condition once the short circuit rectified.
  • YELLOW LED indication on the side of the base for short circuit Identification.

REPEATER PANEL

  • As per UL 864, 9th Edition & NFPA 72
  • 160 (40X4) character LCD display.
  • Real Time Clock.
  • On Board RS 485 Communication Port
  • USB 2.0 Interface for PC Connectivity.
  • One form C relay for Fire.
  • Extensive, built-in transient protection.
  • Lamp test Facility.
  • Touch keypad.

MASTER PANEL (FGHMX-MP)

  • Master Mic Control.
  • Led Switch Control Points.
  • Dual Channel DMR.
  • 1000 pre recorded message
  • High Speed Communication Loop
  • Capacity of 2048 control and monitor points.
  • Self Diagnostic routines.
  • All call operation.
  • Alarm by zone operation.
  • Contact closure activation for appropriate zones.
  • Integrated Master Fire Phone (Optional)
  • Warden Stations (Optional)
  • Fibre Optic Network Capable (Optional)
  • Maximum System Configuration up to 1000 switch/input points.(optional).